STATIC FAILURE OF THE ADHESIVE AND COMBINATION JOINTS ON COLD-FORMED STEEL JOINT USING A COHESIVE ZONE MODEL APPROACH

Authors : Siti Nur Rahmah Anwar; Siti Aminah Anwar; Priyo Suprobo; Endah Wahyuni; Faimun Faimun
article cite 4 Year 2018
source: Jurnal Teknologi
Abstract

A research of new connection method due to axially static loading on the cold-formed steel in civil engineering structures has been investigated. Joint failure was modeled with a cohesive zone model (CZM) approach where the governing parameters were determined from fracture mechanics test specimens. The incremental in capacity strength of cold-formed steel single lap joints (SLJs) was successfully predicted. Video microscope records carried out on the failure surface of the joints in experimental works. The modeling results have a good correlation with the experimental works. Strength capacity deviation of experimentation to FEM are 21.93%, 18.5%, 36.3%, 12.47% and 4.03% for srew, epoxy resi adhesive, polyester resin adhesive, combination screw with epoxy resin and combination screw with polyester resin connections.


Concepts :
Structural Behavior of Reinforced Concrete
Structural Load-Bearing Analysis
Engineering Structural Analysis Methods
article cite 4 Year 2018 source Jurnal Teknologi
SDGs
Sustainable cities and communities
Citations by Year
YearCount
2018 4