Abstract
Abstract In this study, analysis of radiation parameters (linear attenuation coefficient, mean free path and half value layer) of pumice constituent compounds was carried out. Analyzes were done on the compounds of Al 2 O 3 , Fe 2 O 3 , SiO 2 , CaO, K 2 O and Na 2 O with a theoretical approach using the XCOM program for gamma photon energies 57 Co (0.122 MeV; 0.1365 MeV), 133 Ba (0.356 MeV), 54 Mn (0.835 MeV), 137 Cs (0.662 MeV), 60 Co (1.173 MeV; 1.333 MeV), 65 Zn (1.1155 MeV), 22 Na (0.511 MeV; 1.275 MeV) and 40 K (1.461 MeV). The results show that the Fe 2 O 3 compound has the largest linear attenuation coefficient, while the largest for MFP and HVL is Na 2 O among other compounds.
Concepts :
Radioactivity and Radon Measurements
Radiation Shielding Materials Analysis
Advanced X-ray and CT Imaging
article
cite 3
Year 2021
source Journal of Physics Conference Series